How do I size a refrigerated air dryer for my shop?

Size a refrigerated dryer by the compressor's full flow in CFM, then apply the maker's correction factors for inlet air temperature, ambient temperature and pressure, because hot inlet air or a hot room reduces a dryer's real capacity.

Read the full answer →

What is the difference between a cycling and non-cycling refrigerated dryer?

Short answer: A non-cycling refrigerated dryer runs its refrigeration system continuously regardless of air demand, while a cycling dryer uses thermal storage or controls to turn the refrigeration off at low demand, saving energy in shops with variable use.

Non-cycling dryers are simpler and usually less expensive to buy. They provide consistent dew point but use power even when little air is flowing.

Cycling dryers store cold in a thermal mass or use variable controls, allowing the compressor in the dryer to stop and restart as needed. They cost more upfront but can save energy where air demand changes through the day.

Both types need clean condensers, working drains and proper ventilation.

Follow the maker's maintenance schedule, lock out power before service and wear eye protection when draining.

How does a heatless desiccant dryer regenerate?

Short answer: A heatless desiccant dryer uses two towers; while one dries the air, the other is regenerated by a portion of dry compressed air purged through it at low pressure, then the towers switch on a timed or controlled cycle.

Desiccant beads adsorb moisture from compressed air, reaching very low dew points suitable for paint, instrument air and cold climates. They eventually become saturated and must release the moisture.

Heatless designs use dry purge air to strip moisture from the saturated tower. The purge air is a cost, often a noticeable percentage of the dryer's rated flow.

Heated and blower-purge designs reduce purge air but cost more.

Install a coalescing prefilter to protect desiccant from oil and a particulate afterfilter to catch desiccant dust. Release pressure before servicing, and wear eye protection.

Tools used for this job

DeVilbiss 130525 QC3 Desiccant Dryer

Where should an air dryer be installed in a shop system?

Short answer: Most dryers go after the compressor and receiver tank, after a water separator or aftercooler and before the main distribution piping, so air is cooled and bulk water is removed before drying.

Hot air straight from the compressor holds a lot of moisture and can overload a dryer. Letting it cool in the receiver and passing it through a separator reduces the load.

A filter before the dryer protects it from oil and particles. Bypass valves let you service the dryer without shutting down the shop.

Point-of-use desiccant dryers can be added at paint guns or sensitive equipment.

Make sure the dryer has ventilation and access for maintenance. Wear eye protection when servicing.

Tools used for this job

DeVilbiss 130500 Desiccant Air Dryer System CT-30

Why is water still getting past my refrigerated dryer?

Short answer: Water past a refrigerated dryer usually means the dryer is overloaded by heat or flow, its drain has failed, the condenser is dirty, the refrigerant circuit is low or the dryer is bypassed or switched off.

Refrigerated dryers chill the air to condense moisture and then drain it away. If the drain clogs, collected water is carried downstream. Check the drain first, since it is the most common and easiest fault.

A dirty condenser or a hot room reduces cooling. Clean the condenser fins and make sure the dryer has fresh air around it. If air leaving the dryer is not noticeably cool, the refrigeration side may need service by a qualified technician.

Flow above the dryer's rating or very hot inlet air from a compressor without enough cooling overwhelms it. Compare the compressor's output with the dryer's corrected capacity.

Also check that bypass valves are closed and that water is not entering from piping that was wet before the dryer was installed. Lock out power before service and wear eye protection.

Tools used for this job

DeVilbiss 130500 Desiccant Air Dryer System CT-30

What is a membrane air dryer?

Short answer: A membrane dryer passes compressed air through bundles of hollow fibers that let water vapor escape through the fiber walls, drying the air without electricity or refrigerant, and is mainly used for low-flow point-of-use applications.

Membrane dryers are compact, quiet and have no moving parts. A small portion of dried air is used as sweep air to carry away moisture, which is a cost to consider.

They are often used for instruments, small paint stations or remote equipment where power is unavailable.

They require good prefiltration, since oil and particles can damage the fibers.

Follow the maker's sizing and filter requirements, and wear eye protection when servicing pressurized parts. Membrane performance depends on inlet pressure and flow, so check the maker's chart for your conditions.

What is a deliquescent air dryer?

Short answer: A deliquescent dryer uses tablets that absorb moisture and dissolve into a liquid that is drained away, providing moderate drying without power, and is often used outdoors or in remote locations.

These dryers are simple and have no moving parts. The tablets are consumed over time and must be refilled.

They provide a moderate dew point suppression, not as low as desiccant dryers.

The drained liquid can be corrosive, so dispose of it according to local rules.

Keep the vessel properly maintained and wear eye protection and gloves when refilling. Because the drying effect depends on temperature, deliquescent dryers work best where air is cooled before it enters the vessel. They are sometimes used on portable construction compressors and remote sites where a refrigerated dryer is not practical. Check the tablet level often during humid seasons, since consumption rises with moisture load.

How do I maintain a refrigerated air dryer?

Short answer: Keep the condenser clean, check that the automatic drain works, replace prefilter elements on schedule, watch the dew point or temperature indicator and keep the area around the dryer ventilated and free of dust.

Dust on the condenser reduces cooling and is a common cause of poor performance. Clean it with low-pressure air or a brush with power locked out.

Test the drain regularly by pressing its test button or watching it cycle.

Check the dryer's indicator for proper operation and note any warnings.

Have refrigeration repairs done by qualified technicians. Wear eye protection when draining. Many shops add dryer checks to a weekly compressor room routine, along with draining the tank and checking for leaks. Keep a log of readings so you notice gradual changes before water reaches tools and paint. Make sure the dryer's electrical supply and ventilation stay as the installer specified.

Tools used for this job

DeVilbiss 130500 Desiccant Air Dryer System CT-30

Do I need an air dryer if I already have a water separator?

Short answer: A water separator removes liquid water but not water vapor, so air can still condense downstream as it cools; if you paint, blast, run plasma cutters or work in humid or cold conditions, a dryer adds protection a separator cannot.

Separators work by spinning or slowing the air so liquid droplets fall out. They are effective and inexpensive, and every system should have them at key points. But air leaving a separator is still saturated with vapor at its current temperature.

When that air travels through cooler piping or expands at a tool, more water condenses. That is why shops with only separators still see water in hoses on humid days or in winter.

A refrigerated dryer lowers the dew point so less water can condense later. A point-of-use desiccant dryer at a paint gun gives extra protection where it matters most.

For general tool use in a dry climate, separators and daily tank draining may be enough. Release pressure before servicing any filter or dryer, and wear eye protection when draining.

Tools used for this job

S&G Tool Aid 99000 In-Line Water Separator and Air FilterDeVilbiss 130500 Desiccant Air Dryer System CT-30

What dew point do I need for automotive painting?

Short answer: Paint makers usually want air free of liquid water and oil, and many shops aim for a refrigerated dryer dew point around 35 to 40 degrees F plus point-of-use filtration, or lower dew points with desiccant dryers in cold areas; follow your paint maker's guidance.

Moisture in paint air causes blushing, fisheyes and adhesion problems. The key is that the air's dew point stays below the coldest temperature the air sees on its way to the gun.

Refrigerated dryers handle most heated shops. Desiccant dryers or point-of-use desiccant units add protection for cold piping or humid climates.

Coalescing filters remove oil aerosols that dryers do not.

Wear a respirator and eye protection when painting, and follow the paint and booth maker's air quality requirements. Test the air at the gun periodically.

Tools used for this job

DeVilbiss 130525 QC3 Desiccant Dryer

General guidance only. Follow the vehicle and tool manufacturer's procedures, and confirm vehicle coverage on the tool maker's list before buying.